PSEUDO-PEA VERSUS TRUE PEA: CONTRIBUTION OF ULTRASONOGRAPHY TO RECOGNITION AND PROGNOSIS

Authors

  • Andressa Cristiane Pereira Trevizan
  • Gustavo Gonçalves Cândido
  • Ruan Dolinski Sates
  • Priscila Andretta
  • Tayná Zolet
  • Marco Antonio Schueda

DOI:

https://doi.org/10.56238/sevened2026.027-056

Keywords:

Heart Arrest, Cardiopulmonary Resuscitation, Ultrasonography, Prognosis

Abstract

Pulseless electrical activity (PEA) is a non-shockable cardiac arrest rhythm characterized by the presence of organized electrical activity without a clinically detectable arterial pulse. The use of point-of-care ultrasound (POCUS) enables the distinction between different physiological states, including true PEA, characterized by the absence of significant cardiac mechanical activity, and pseudo-PEA, in which cardiac contractility persists despite the absence of a palpable pulse. This study aimed to describe the pathophysiological differences between these conditions and to analyze the contribution of POCUS to their recognition, prognostic assessment, and management during resuscitation. This is a descriptive-exploratory, qualitative literature review comprising 12 studies and scientific documents published between 2020 and 2026. The evidence analyzed demonstrated that the presence of residual mechanical activity in pseudo-PEA is associated with a higher probability of return of spontaneous circulation and survival compared with true PEA. In addition, POCUS may assist in identifying potentially reversible causes of cardiac arrest. It is concluded that distinguishing between these phenotypes provides relevant information for the assessment of patients with PEA; however, ultrasound findings should be interpreted in conjunction with clinical and physiological parameters and should not be used in isolation for prognostic decisions or termination of resuscitation efforts.

References

ALCANTARA, Monica Luiza de et al. Posicionamento sobre o uso do ultrassom “Point of Care” (POCUS) na medicina cardiovascular – 2026. Arquivos Brasileiros de Cardiologia, v. 123, n. 4, e20260222, 2026. DOI: 10.36660/abc.20260222. Acesso em 10 set. 2026

ANTO, A. M. et al. Point-of-care-ultrasound in cardiac arrest: a useful tool for resuscitation. Frontiers in Medicine, Lausanne, v. 13, art. 1795346, 2026. DOI: 10.3389/fmed.2026.1795346. Acesso em: 09 set. 2026.

ELHALWAGY, O. et al. Contextualizing pseudo-pulseless electrical activity in cardiac arrest: a meta-analysis and systematic review. Air Medical Journal, v. 44, n. 1, p. 83-92, 2025. DOI: 10.1016/j.amj.2024.11.010. Acesso em: 10 set. 2026.

HADDAD, Ghania et al. Doppler ultrasound peak systolic velocity versus end tidal carbon dioxide during pulse checks in cardiac arrest. Resuscitation, Limerick, v. 183, art. 109695, fev. 2023. DOI: 10.1016/j.resuscitation.2023.109695. Acesso em 09 set. 2026

HORIKOSHI, Y. et al. Potential return of spontaneous circulation in Japanese out-of-hospital cardiac arrest patients with pseudo-pulseless electrical activity: a post hoc analysis of a prospective multicentric study. Resuscitation Plus, v. 29, art. 101327, 2026. DOI: 10.1016/j.resplu.2026.101327. Acesso em: 10 set. 2026.

INTERNATIONAL LIAISON COMMITTEE ON RESUSCITATION. Advanced Life Support: 2025 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Circulation. 2025. DOI:10.1161/CIR.0000000000001360. Acesso em: 10 set. 2026

JIAN, S. J. Z.; CHENG, T. H.; YEN, C. C. Prognostic accuracy of point-of-care ultrasound in patients with pulseless electrical activity: a systematic review and meta-analysis. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, v. 33, art. 27, 2025. DOI: 10.1186/s13049-025-01327-0. Acesso em: 10 set. 2026.

NARALA, B. et al. Point-of-care-ultrasound in in-hospital cardiac arrest. Resuscitation Plus, v. 30, art. 101385, 2026. DOI: 10.1016/j.resplu.2026.101385. Acesso em: 10 set. 2026.

RABJOHNS, J. et al. Pseudo-pulseless electrical activity in the emergency department, an evidence based approach. The American Journal of Emergency Medicine, v. 38, n. 2, p. 371-375, 2020. DOI: 10.1016/j.ajem.2019.158503. Acesso em: 10 set. 2026.

REYNOLDS, Joshua C. et al. Diagnostic test accuracy of point-of-care ultrasound during cardiopulmonary resuscitation to indicate the etiology of cardiac arrest: a systematic review. Resuscitation, Limerick, v. 172, p. 54–63, mar. 2022. DOI: 10.1016/j.resuscitation.2022.01.006. Acesso em 07 set. 2026

WIGGINTON, J. G. et al. Part 9: adult advanced life support: 2025 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation, v. 152, supl. 2, p. S538-S577, 2025. DOI: 10.1161/CIR.0000000000001376. Acesso em: 10 set. 2026.

ZAKI, Hany A. et al. The role of point-of-care ultrasound (POCUS) imaging in clinical outcomes during cardiac arrest: a systematic review. The Ultrasound Journal, Milano, v. 16, n. 1, art. 4, jan. 2024. DOI: 10.1186/s13089-023-00346-1. Acesso em 07 set. 2026